HANNA HI1295 Spare Electrode for HI98113 Piccolo 3

HANNA HI1295 Spare Electrode for HI98113 Piccolo 3





Spare Electrode for HI98113 Piccolo 3

Details

Spare Electrode for HI98113 Piccolo 3

Specifications

Referencesingle, Ag/AgCl
Junction / Flow Rateceramic, single / 15-20 μL/h
Electrolytegel
Max Pressure2 bar
RangepH: 0 to 13
Recommended Operating Temperature0 to 70°C (32 to 158°F)
Tip Shapespheric (dia: 5 mm)
Temperature Sensoryes
Amplifieryes
Body Materialpolypropylene
Cableno
Applicationsfield applications, general purpose
Connectionmulti-pin

HANNA HI7609829-0 Double Junction pH Sensor for HI9829

HANNA HI7609829-0 Double Junction pH Sensor for HI9829 Multiparameter Portable Meter








he HI7609829-0 is a replaceable pH sensor for use with Hanna’s HI9829 multiparameter portable meter. The sensor body is constructed of durable PEI material and contains a double junction design. The HI7609829-0 contains a glass pH sensing tip combined with a Ag/AgCl reference electrode in gel electrolyte. Each module is color coded for easy installation and integration with the probe.
PEI Body

PEI Sensor Body

ceramic double junction

Ceramic Double Junction Reference

color coded

Color Coded Sensor

Details

PEI Sensor Body

The PEI (polyetherimide) electrode body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. The PEI plastic is a high quality plastic that is chemically resistant to many harsh chemicals.

Ceramic Double Junction Reference

A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or silver precipitates on the junction are likely to form.

Color Coded Sensor

Sensors are color coded to match sensor ports on the probe for quick, field-replaceable, screw-type, connection and identification.

Specifications



SensorHI 7609829-0
DescriptionpH sensor
Measurement TypepH, pH-mV
Measurement Range0.00 to 13.00 pH ; ±600.0 pH-mV
Temperature Range-5 to 55 °C
Color Codered
Tipglass (pH)
Junctionceramic
BodyPEI
Electrolytegel
Referencedouble
MaintenanceHI70300 (storage solution)
Dimensions118 x 15 mm
Depth20 m (65’)

HANNA HI10530 - Digital pH/Temperature Electrode

HANNA HI10530 - Digital pH/Temperature Electrode








The HI10530 is a digital glass body, refillable, double junction pH electrode that has a built in temperature sensor and connects to the meter with a 3.5 mm connector. This type of connector is proprietary to meters that use digital electrodes. The HI10530 pH electrode has a triple ceramic junction in the outer junction and the conical pH sensing portion is made with low temperature glass. This design consideration is ideal for emulsions, fats and creams, soil and semi-solid samples, low conductivity solutions, and for measuring samples at cold temperatures.
digital electrode

Built-in Microchip

conical tip

Built in temperature sensor

Triple Ceramic

Triple Ceramic Junction

Details

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.
The HI10530 is a digital electrode that has low temperature (LT) glass, conical bulb, glass body, triple ceramic junction and is refillable with 3.5M KCl.

digital electrode

Built-in Microchip

The built-in microchip stores sensor type, serial number and calibration information including date, time, offset, slope, probe condition and buffers used. This information is automatically retrieved by edge® once the electrode is plugged in. The ability to transfer information allows for hot swapping of probes without having to recalibrate. 

All pH measurements are performed within the electrode and transferred digitally to the meter. This overcomes any noise issues associated with the traditional high impedance analog measuring system. Electrical noise can be generated from a built in temperature sensor and while working in a humid environment.
digital electrode

Low Temperature Glass Formulation

The measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25oC while the resistance of LT glass is around 50 megaohms at 25oC. As the temperature of the glass decreases in the sample, the resistance of the LT glass will approach that of GP glass. If using GP glass, the resistance would increase above the optimum range, resulting in increased impedance and ultimately affecting the measurement. The HI10530 is suitable to use with samples that are between -5 to 100oC.
conical-tip

Conical Glass Tip

The conical shaped tip design allows for penetration into solids, semi solids, and emulsions for the direct measurement of pH in food products, soil, and emulsions like hand creams.
glass-body

Glass Body

The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allow for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.

open junction

Built in Temperature Sensor

HI10530 features a built-in thermistor temperature sensor that is in the tip of the indicating pH electrode. A thermistor temperature sensor provides for a high accuracy temperature reading and should be as close as possible to the indicating pH electrode in order to compensate for the effect that temperature has on the membrane potential. By having an accurate reading it is possible to provide an accurate temperature compensated reading.

open junction

Triple Ceramic Junction

The triple ceramic junction allows a faster flow rate of electrolyte from the reference into the solution. A standard pH electrode will use a single ceramic junction that allows for 15 to 20 µL/hour of electrolyte to flow; the HI10530 has three ceramic junctions, providing for 40 to 50 µL/hour of electrolyte to flow. This high flow rate provides faster electrode response and more stable measurement in viscous solutions or samples of low conductivity, such as pure water, where a long stabilization time is often observed.

double junction

Double Junction Reference

A double junction electrode has an internal compartment surrounding the reference wire. Silver ions are present in the electrolyte of the internal compartment, which houses the Ag/AgCl reference wire; the electrolyte outside this compartment is silver free. The double junction design means that virtually no silver from the electrode enters the sample. This design allows measurement in applications where silver ions in the sample are undesirable or for samples that contains sulfides that can cause the silver to precipitate and clog the junction. Clogging of the junction will result in drifty and erratic readings.

refillable

Refillable

The HI10530 is a refillable probe. Since it is a double junction pH electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode.

3.5 mm

3.5 mm Connector

The HI10530 uses a 3.5 mm connector that makes attaching and removing the probe simple and easy. This type of connector is proprietary to the meter. Compatible meters include the edge (HI2002, HI2020, HI2030, and HI2040).

single vs double junction

Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal refernce wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.
Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free”. Since there is no silver present, there is no precipitate forming to clog the junction.

Specifications

Body Materialglass
Referencedouble, Ag/AgCl
Junction / Flow Rateceramic, triple / 40-50 μL/h
Electrolyte3.5M KCl
RangepH: 0 to 12
Max Pressure0.1 bar
Tip Shapeconic (12 x 12 mm)
Diameter12 mm
Body Length / Overall Length120 mm / 175.5 mm
Recommended Operating Temperature-5 to 100°C (23 to 212°F) - LT
Temperature Sensoryes
Matching Pinno
Amplifieryes
Digitalyes
Cablecoaxial; 1 m (3.3’)
Connection3.5 mm connector
Applicationsemulsions, fats and creams, low conductivity solutions, potable water, semi-solid products, soil samples

HANNA HI7698194 Multiparameter Probe for HI98194

HANNA HI7698194 Multiparameter Probe for HI98194

T


The HI7698194 is a multiparameter pH/EC/DO/Temperature probe for use with the HI98194 portable meter. It features a quick connect that makes a waterproof connection with the meter. Sensors are automatically recognized by the probe and meter when connected. Sensor replacement is quick and easy with field replaceable, screw type connectors that are color coded for easy sensor identification. The probe features a multistrand-multiconductor shielded cable with 4m, 10m, 20m, and 40m lengths available. It’s rugged, waterproof design makes it ideal for field use.
Multi-function sensor

Color Coded, Field Replaceable Sensors

quick connect

Quick Connect

calibration beaker

IP68 Rating

Details


Features at-a-glance

Waterproof Protection - The HI7698194 probe features an IP68 rating for continuous immersion in water.
Quick Connect Digital Probe - The HI7698194 probe features a Quick Connect DIN connector that makes a waterproof connection with the meter. 
Color Coded, Field Replaceable Sensors - Sensor replacement is quick and easy with field replaceable, screw type connectors that are color coded for easy sensor port identification.
Auto-sensor Recognition - The probe and meter automatically recognize the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.
Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.

Available Sensors

pH sensor


The HI7698194-0 is a replaceable pH sensor for use with Hanna’s family of mulitparameter portable meters and probes. The sensor body is constructed of durable PEI material and contains a double ceramic junction design. The HI7698194-0 contains a glass pH sensing tip combined with a Ag/AgCl reference electrode in gel electrolyte. Each module is color coded for easy installation and integration with the probe.

pH sensor

The HI7698194-1 is a replaceable pH/ORP sensor for use with Hanna’s family of mulitparameter portable meters and probes. The sensor body is constructed of durable PEI material and contains a double ceramic junction design. The HI7698194-1 contains a glass pH sensing tip with a platinum ORP sensing pin. Each module is color coded for easy installation and integration with the probe.


EC sensor

The HI7698194-3 is a replaceable 4 ring electrode conductivity sensor for use with Hanna’s family of mulitparameter portable meters and probes. The sensor body is constructed of durable ABS material and contains AISI 316 stainless steel electrodes that are not subject to polarization or surface coating effects. Each module is color coded for easy installation and integration with the probe.


DO sensor

The HI7698194-2 is a replaceable galvanic dissolved oxygen membrane sensor for use with Hanna’s family of mulitparameter portable meters and probes. The sensor body is constructed of durable ABS material and contains an easily replaceable membrane cap design. The membranes are constructed of HDPE and each cap screws onto the sensor with the twist of a finger. The HI7698194-2 sensor contains a silver cathode and zinc anode. The sensor module is color coded for easy installation and integration with the probe.

Specifications


ProbeHI7698194
Sensor Inputs3 (pH or pH/ORP, EC, DO)
Sample EnvironmentFresh, brackish, seawater
Waterproof ProtectionIP68
Operating Temperature-5 to 55 °C
Storage Temperature-20 to 70 °C
Maximum Depth20 m (66’)
Dimensions (without cable)342 mm (13.5”); 46 mm (1.8”) diameter
Weight (without batteries and sensors)570 g (20.1 oz.)
Cable Specificationmultistrand-multiconductor shielded cable with internal strength member rated for 68 kg (150 lb.) intermittent use.
Wetted MaterialsBody: ABS, O-rings: EPDM, Shield: ABS / 316 SS, Temperature Probe: 316 SS, Threads: Nylon