KOEHLER K8610-1003 Ethanol Purity & Methanol

KOEHLER K8610-1003 Ethanol Purity & Methanol Content by Gas Chromatograph


K8610-1003 Ethanol Purity & Methanol Content by Gas Chromatograph
• Highly-configurable, low-cost, compact & portable
• Ambient-to-400C temperature-programmable column oven
• Electronic Pressure Control (EPC) of all GC system gases, including carrier gas
• LED "at-a-glance" display of all temp, pressure, & voltage-controlled zones
Includes:
• Flame Ionization Detector (FID)
• Single-channel USB 2.0-compliant data acquisition hardware
• PeakSimple data acquisition & control software for WinXP on IBM PC
• 6' USB 2.0 Cable (A to B)
• GC Accessory Kit
• Reusable shipping crate for safe portability
• Operation & Service Manuals
• Free software updates



Click on the image to view a larger photo of the instrument.

Test MethodASTM D5501 covers the determination of the ethanol content of denatured fuel ethanol by Gas Chromatography. Ethanol is determined from 93 to 97 mass % and methanol is determined from 0.1 to 0.6 mass %. ASTM D5501 does identify and quantify methanol but does not purport to identify all
individual components that make up the denaturant. This test method
provides a method of determining the percentage of ethanol (purity) of the fuel ethanol that is blended into gasoline.

Gas Chromatograph
The Gas Chromatography 8610 serial chassis can be configured to perform and satisfy all of the requirements of either ASTM D5501 or EN 14110 for Ethanol purity and Methanol content. Analysis takes about 25 minutes and is simple enough for an untrained operator to perform in the lab or in the field. The included PeakSimple Data System displays the calibrated results directly without off-line calculations.

Specifications
Conforms to the specifications of: ASTM D5501, EN 14110

Dimensions lxwxh,in.(cm)
19 x 14.5 x 12.5 (48.5 x 36.75 x 30.5)
Net Weight: 37 lbs (16.8 kg)

Shipping InformationShipping Weight: 52.5 lbs (23.9 kg)
Dimensions: 4.9 Cu. ft.

Ordering Information
Catalog
Number
Product Description
K8610-1003Gas Chromatograph, 8610C serial chassis,
110V 60Hz
K8690-0010Required Configuration for D5501Flame Ionization Detector (FID)
K8690-0034Heated Split-Splitless Injector Upgrade
K8600-WBCXMXT-1 Capillary Column (105M x0.25mm ID, 0.5 DB-1)
K8690-0010Required Configuration for EN 14110Flame Ionization Detector (FID)
K8690-0034Heated Split-Splitless Injection Port Upgrade
K8690-0045Heated Static Headspace Injector Upgrade
K8600-WBWBMXT-WAX Capillary Column (30M x 0.53mm ID x 0.5 ยต)

Accessories
Catalog
Number
Product Description
K8680-0350
Optional Hydrogen Generator
K8690-0070
Optional built-in air compressor
K8600-C590Gas Line Installation Kit for Air Cylinder (FID)
K8600-C350Gas Line Installation Kit for Hydrogen Cylinder (FID)
K8600-C580Gas Line Installation Kit for Helium Cylinder (carrier gas)