LF9648

Conductivity Meter
4-digit, 14.2 mm red,
Measuring range programmable,
Temperature compensation via Pt100/Pt1000,
max. 4 alarm outputs,
Supply voltage:
24 V DC, 24 V AC, 115 V AC, 230 V AC,
Panelmeter DIN 96x48mm
Direct connection of 2- or 4- electrode cells,
0..2000 mS/cm


LF1010

Conductivity Meter
4-digit, 14.2 mm red,
Measuring range programmable,
Temperature compensation via Pt100/Pt1000,
max. 2 alarm outputs,
Supply voltage:
24 V DC, 24 V AC, 115 V AC, 230 V AC,
Field mounting
Direct connection of 2- or 4- electrode cells,
0..2000 mS/cm


UNICON-LF

Conductivity-Converter
Measuring range programmable,
Temperature compensation via Pt100/Pt1000,
Output 4..20 mA for
conductivity and temperature,
max. 2 alarm outputs,
Supply voltage: 14..30 V DC,
Loop powered,
Field- or head mounting

Direct connection of 2- or 4- electrode cells,
0..2000 mS/cm


GLMU


Conductivity Transmitter incl. Cell
Temperature compensation,
Output 0..1/10 V (3-wire)
4..20 mA (2-wire),
LC-Display 4 digit,
Supply voltage:
12..30 V DC at 4..20 mA
18..30 V DC at 0..10 V
Direct connection of 2- or 4-electrode cells via plug
200 µS/cm..500 mS/cm

Conductivity Cells


LF2203


2-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U DIN 8061/8062, Graphite (electrodes)
For flow fitting DFA25
Pipe diameter 25..63 mm,

Measuring range:
100 µS/cm..2 mS/cm


LF2603


2-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U DIN 8061/8062,
SS-type (electrodes)
Process thread G1/2A, G3/4A, R1/2, G3/4,

Measuring range:
20 µS/cm..100 µS/cm


LF2613


2-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U DIN 8061/8062,
Electrodes (Graphite)
Process thread G1/2A, G3/4A, R1/2, G3/4

Measuring range:
100 µS/cm..2 mS/cm


LF2653HT


2-Electrode High Temperature
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Temperature range 0..200 °C,
Process material SS-type 1.4404, ceramic
Process thread G3/4A, G1A, G1 1/4A

Measuring range:
0.5 µS/cm..50 µS/cm


LF1453/LF2453


2-Electrode Ultra-pure water
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material SS-type, PVDF,
Field or head mounting
Clamp-connection acc. to DIN 32676 or Südmo-Aseptik

Measuring range:
0.5 µS/cm..50 µS/cm


LF1553/LF2553


2-Electrode Ultra-purewater
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material SS-type 1.4404, PEEK,
Field or headmounting
VARIVENT Inline-case

Measuring range:
0.5 µS/cm..50 µS/cm


LF1653/LF2653


2-Electrode Ultrapure water
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material SS-type 1.4404 electropolished, PVDF,
Field or headmounting
Process thread G3/4A, G1A

Measuring range:
0.5 µS/cm..50 µS/cm


LF4003                


4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U, casting resin, SS-type 1.4305, Graphite (electrodes), PUR cable
Immersion Cell up to 100 m depth of water

Measuring range:
20 µS/cm..500 mS/cm


LF3043/LF4043                


4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PA, casting resin, Graphite (electrodes)
Field- or head mounting
Immersion-cell for ducts, basins and open systems

Measuring range:
20 µS/cm..500 mS/cm


LF3213/LF4213                


4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVC-U, casting resin, Graphite (electrodes)
Field- or head mounting
For Flow fitting DFA32
and pipe diameter 20..63 mm

Measuring range:
20 µS/cm..500 mS/cm


LF3433/LF4433                


4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PEEK, PVDF, SS-type 1.4404, Graphite (electrodes)
Field- or head mounting
Clamp-connection acc.. to DIN 32676

Measuring range:
20 µS/cm..500 mS/cm


LF3533/LF4533                


4-Electrode Hygienic
Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PEEK, SS-type 1.4404, Graphite (electrodes)
Field- or headmounting
VARIVENT Inline-case

Measuring range:
20 µS/cm..500 mS/cm


LF3623/LF4623                


4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PVDF, casting resin, Graphite (electrodes)
Field- or headmounting
Process thread G3/4A, G1A acc. to DIN ISO 228

Measuring range:
20 µS/cm..500 mS/cm


LF3733/LF4733                


4-Electrode Conductivity Cell
integrated Pt1000 sensor for temperature compensation,
Process material PEEK, PVDF, SS-type 1.4404, casting resin, Graphite (electrodes),
Field- or headmounting
Milk pipe connection acc. to DIN 11887,

Measuring range:
20 µS/cm..500 mS/cm