Rabu, 17 Februari 2016

Hioki Oscilloscopes | Memory Recorders

Data Acquisition (DAQ) for R&D and Testing Applications


MEMORY HiCORDER   MR8847A

High-speed 20MS/s, 16-channel, Fully Isolated Memory Recorder for On-site Jobs and R&D
 
• Max. 16ch Analog + 16ch Logic • Max. 10ch Analog + 64ch Logic • 20M-Sampling/s • 32M to 256M-Word Memory (2ch) • Waveform judgment function • 12-bit/16-bit A/D resolution • USB, HD, CF-card

MEMORY HiCORDER   MR8827

High-speed 20MS/s 32-channel Fully-isolated Memory Recorder Provides Simultaneous Data Acquisition Over 32 Analog + 32 Logic Channels
 
• Max. 32ch Analog + 32ch Logic • Max. 28ch Analog + 64ch Logic • 20M-Sampling/s • 16M to 128M-Word Memory (4ch) • 12-bit/16-bit/24-bit A/D resolution • USB, SSD, CF-card

MEMORY HiCORDER   MR8740, MR8741

High-speed, 54- or 16-channel Memory Recorders Provide Advanced Data Acquisition and Rack-Mount Systems Integration
 
• Max. 54ch/16ch Analog + 16ch Logic • 20M-Sampling/s • 12-bit/16-bit A/D resolution

MEMORY HiCORDER   MR8875

1000V Direct Input, Portable 16-channel Memory Recorder for Data Acquisition During Vehicle Testing with Direct CAN Bus Input
  
 
• Max. 16ch Analog + 8ch Logic • 60ch scanner • 500k-Sampling/s • 16-bit A/D resolution

MEMORY HiCORDER   8860-50, 8861-50

High-speed 16- or 32-channel Memory Recorders Offer Data Acquisition, Oscilloscope and Data Logger Functionality to Record Waveforms in Any Situation
 
• Max. 16ch/32ch Analog + 16ch Logic, or 64ch/128ch w/Scanner Unit • 20M-Sampling/s • 12-bit/16-bit A/D resolution



Data Acquisition (DAQ) for Service, Maintenance, and Production Applications

MEMORY HiCORDER   MR8870

A Single Memory Recorder that can Observe Waveforms like an Oscilloscope and Record RMS Value Fluctuations
 
• 2ch Analog + 4ch Logic • 1M-Sampling/s • 12-bit A/D resolution

MEMORY HiCORDER   MR8875

1000V Direct Input, Portable 16-channel Memory Recorder for Data Acquisition During Vehicle Testing with Direct CAN Bus Input
  
 
• Max. 16ch Analog + 8ch Logic • 60ch scanner • 500k-Sampling/s • 16-bit A/D resolution

MEMORY HiCORDER   MR8880

Portable Memory Recorder for High Voltage Testing and Fully Isolated Data Acquisition Across 4 Channels
 
• Max. 4ch Analog + 8ch Logic • 1M-Sampling/s • 14-bit A/D resolution



Pen Recorders

PEN RECORDER   PR8111, PR8112

1- or 2-Pen Chart Recording of DC Voltage Signals with an Easy-to-Use Portable Pen Recorder
 
• 150 mm (5.91 in) chart width, compact size • 1 pen: PR8111 • 2 pens: PR8112 • Power with AC adapter or dry cell batteries



Data Acquisition PC Software

iPad App for Memory HiCorder   HMR Terminal

Analyze Memory HiCorder waveforms right on your iPad
 
• For Memory HiCorder • (Exclusively for Apple Inc. iPad) Free download from the App Store

MEMORY HiVIEWER   9725

Windows Software Provide Advanced Analysis of Measurement Data Recorded by the Hioki 8860 Series Memory HiCorders
 
• Achieve functions identical to those of the Memory HiCorder 8860 Series on a PC

WAVE PROCESSOR   9335

Windows Software Provide Advanced Analysis of Measurement Data Recorded by Hioki Memory HiCorders
 
• Convert data, print and display waveforms

LAN COMMUNICATOR   9333

Networking Software Lets You Remotely Control Memory Recorders via a LAN Connection
 
• For LAN communication with the MR8740/8741, MR8847 series, 8826 • For data collection and remote control



Memory Recorder Options


ARBITRARY WAVEFORM GENERATOR UNIT   U8793

Pair with Memory Recorders to Achieve a Single-device Solution for Waveform Recording and Generation
 
・2ch, 10 mHz to 100kHz function generator ・Arbitrary waveform generator function 2 MHz D/A refresh rate ・Max.15 V output

PULSE GENERATOR UNIT   MR8791

Pulse Generator Input Module for Control Simulation Testing
 
・8 ch ・Pulse output 0.1 Hz to 20 kHz ・Pattern output

WAVEFORM GENERATOR UNIT   MR8790

Waveform Generator Input Module for Control Simulation Testing
 
・4 ch ・DC output ± 10 V ・Sinewave output 10 mHz to 20 kHz

DIFFERENTIAL PROBE   P9000

Easily Connect to Hioki Memory HiCorders and HiLoggers for High Voltage Testing
 
• Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) • For use with input of up to 1 kV AC/DC • Requires separate power supply

LOGIC PROBE   MR9321,MR9321-01

Detect AC/DC voltage with Memory HiCorders
 
• 4 isolated channels • ON/OFF detection of AC/DC voltage • Large terminal type

CAN ADAPTER   8910

Convert CAN Bus Signals Across 12 Channels and Further Analyze Using Recorders or Data Loggers
 
• Select CAN-Bus information and convert them into analog/logic signals • 12ch analog output + 24bit logic output

LOGIC PROBE   9327

Detect the Presence of Voltage or Relay Contact Signals with Memory HiCorders at High-speeds
 
• 4 channels for contact voltage signals • High-speed 100ns response

DIFFERENTIAL PROBE   9322

High Performanc
e Differential Probe Supports 3 Types of Measurements
 
•For up to 2 kV DC or 1 kV AC •Use with AC Adapter 9418-15 •Frequency band width up to 10MHz

LOGIC PROBE   9320-01,9320

Detect the Presence of Voltage or Relay Contact Signals with Memory HiCorders
 
• 4 channels for contact voltage signals • 500ns response • Miniature terminal type

Tidak ada komentar: